Stirrups vs Ties: What They Do, How to Count Them and Their Cut Length

Stirrups and ties are both small bars bent around the main reinforcement, but in the stirrups vs ties question the answer is that they do different jobs. Stirrups are in beams and carry shear, the force that tries to crack a beam diagonally near its supports. Ties are in columns and hold the vertical bars in place so they cannot buckle outward under load. On a takeoff, both are counted the same way: the length of the zone divided by the spacing, plus one, times the cut length of one piece.
Stirrups vs ties: the short version
| Beam stirrups | Column ties | |
|---|---|---|
| Member | Beams, grade beams, some slab bands | Columns, piers, boundary elements of walls |
| Main job | Resist shear | Confine and brace vertical bars |
| Orientation | Vertical loops along a horizontal member | Horizontal loops along a vertical member |
| Shape | Closed or open (U) | Closed, plus crossties |
| Typical callout | #3 STIRRUPS @ 8" | #3 TIES @ 12" |
| Hooks | 90 or 135 degree; 135 where closed hoops are needed | 135 degree on closed ties in most cases |
The question of stirrups vs ties is partly one of naming: the words are sometimes mixed on drawings, and in the UK and many metric markets both are often called "links." Read the member they sit in, not just the word. For the forces behind them, see the video on tension, compression, bending and shear.
Beam stirrups
A beam carries load by bending, but near the supports the shear force is high. Concrete cracks diagonally under shear, and the stirrups cross those cracks and hold them closed. That is why stirrups are often closer together near the supports and farther apart at midspan.
Closed vs open stirrups
An open stirrup is a U shape: two legs and a bottom, with hooks at the top around the top bars. It is used where only shear is the concern and the beam is cast with a slab on top.
A closed stirrup (or hoop) wraps all four sides. It is needed where the beam carries torsion, where the top bars must be held, and in seismic frames. In ACI 318, closed hoops in seismic frames use 135 degree hooks. Hook geometry is covered in rebar hooks and development length.
Multi-leg stirrups
Wide beams may have two stirrups side by side, or an outer closed stirrup plus an inner one, so that four vertical legs cross each crack. The callout will say something like "2 #4 STIRRUPS @ 6"" or show the inner stirrup on the section. Count each piece. A common miss is counting one stirrup per spacing when the section shows two.
Column ties
Vertical column bars are slender. Under heavy compression they can buckle outward and push off the cover. Ties wrap the vertical bars at close spacing and stop that. In seismic columns, closely spaced hoops also confine the concrete core so it can keep carrying load after the cover spalls.
A rectangular column with only four corner bars needs one closed tie per spacing. With more bars, the drawing adds crossties (a straight bar with hooks at both ends) or a second, overlapping tie so that every corner bar and alternate bar is braced. Look at the column section on the schedule: every tie and crosstie shown is one piece per spacing. See column reinforcement explained.
Column ties also continue through the beam-column joint in many designs, and some drawings call for closer spacing at the top and bottom of each column. Check the typical column detail before you count.
How to count stirrups vs ties
The rule is the same for both:
number = roundup( zone length / spacing ) + 1
The "+1" is there because spacing counts gaps, and there is one more bar than gaps. The zone length is the distance from the first stirrup to the last, not the full beam length. Drawings usually locate the first stirrup a short distance from the face of the support, often in a typical detail. Use the distance the drawing gives.
Zones with different spacing
Drawings often split a beam into zones, written like: "#3 STIRRUPS: 1 @ 2", 8 @ 4", REST @ 8"". Count each zone separately and make sure you do not count the stirrup at the boundary twice. When a zone is defined by a number ("8 @ 4"), the count is already given: 8 stirrups.
Worked example: stirrups in a beam
A beam is 12 in wide and 24 in deep, with a clear span of 20 ft between column faces. The beam schedule shows #3 closed stirrups @ 8 in, with 135 degree hooks. The typical detail places the first stirrup 2 in from each column face. Clear cover to the stirrups is 1.5 in.
Step 1: zone length. 20 ft = 240 in. Less 2 in at each end: 240 - 4 = 236 in.
Step 2: count. 236 / 8 = 29.5, round up to 30. Add one: 31 stirrups.
Step 3: stirrup outside dimensions. Width: 12 - 2 x 1.5 = 9 in. Height: 24 - 2 x 1.5 = 21 in.
Step 4: perimeter. 2 x (9 + 21) = 60 in, measured out to out.
Step 5: hooks. A #3 135 degree stirrup hook needs the greater of 6 db (6 x 0.375 = 2.25 in) and 3 in, so 3 in. Two hooks: 6 in.
Step 6: cut length (estimate). 60 + 6 = 66 in = 5.5 ft. This is an estimating approximation: measuring the perimeter out to out slightly overstates the bar's centerline, which roughly offsets the extra steel in the hook bends. A detailer uses bending tables for the exact cut length on the bar list.
Step 7: weight. 31 x 5.5 = 170.5 ft of #3. At 0.376 lb/ft: 170.5 x 0.376 = 64 lb (about 29 kg).
Compare that with the main bars of the same beam. If the beam had 3 #8 bottom bars and 2 #6 top bars, each about 21 ft long, the main bars would weigh about 3 x 21 x 2.670 + 2 x 21 x 1.502 = 231 lb. The stirrups are about 22% of this beam's steel. Stirrups are light bars, but there are many of them, and leaving out a zone or an inner stirrup shows up quickly in the total. The full beam method is in rebar estimate for beams.
Common mistakes with stirrups and ties
- Forgetting the "+1" on every beam. On a building with hundreds of beams it adds up.
- Counting over the full beam length including the column width, when stirrups stop at the column face (or counting through the joint when the details say they continue).
- Missing inner stirrups or crossties shown only on the section.
- Using the beam size as the stirrup size. The stirrup is smaller than the beam by the cover on each side.
- Ignoring zones and using the widest spacing for the whole beam.
More of these are in rebar takeoff mistakes.
Frequently asked questions
What is the difference between a stirrup and a tie?
A stirrup is the transverse bar in a beam and mainly resists shear. A tie is the transverse bar in a column and holds the vertical bars against buckling and confines the core. Both are bent loops around the main bars and are counted the same way.
How do you calculate the number of stirrups in a beam?
Take the length of the zone from the first stirrup to the last, divide by the spacing, round up, and add one. If the beam has zones with different spacing, count each zone separately and do not double count the stirrup at the boundary.
How do you calculate stirrup cut length?
For an estimate, take the stirrup's perimeter (beam size minus cover on each side) and add the two hook extensions. For a 12 x 24 in beam with 1.5 in cover and #3 stirrups with 135 degree hooks, that is 60 + 2 x 3 = 66 in. The bar list will use the fabricator's exact bending deductions.
Why do stirrups have 135 degree hooks?
A 135 degree hook bends back into the core of the member, so it stays anchored even if the cover concrete cracks or spalls. ACI 318 requires 135 degree seismic hooks on hoops and crossties in seismic frames, with an extension of at least 6 bar diameters and 3 in.
Are stirrups closer together near the supports?
Usually, yes. Shear is highest near the supports, so drawings often call for tighter spacing there and wider spacing toward midspan. The beam schedule or elevation gives the zones.
This article explains general practice for learning purposes. On a real project, the drawings, the general notes and the governing code always win.