Beam Rebar Calculation: Bottom Bars, Top Bars and Stirrup Zones

A beam rebar calculation takes four groups of bars separately: bottom bars, continuous top bars, extra top bars over the supports, and stirrups. For the longitudinal bars you work out each bar's length from the beam elevation (span, extension into supports, hooks, laps); for the stirrups you count spaces zone by zone, add one, and multiply by the stirrup cut length. Then convert each group to weight by bar size.
Beams are where the beam elevation and the beam schedule matter most. The plan only tells you where the beam is; almost every bar length comes from the elevation or the typical beam detail.
Reading a beam for the takeoff
On a typical set you will find:
- Framing plan: beam marks (B1, B2) and the column grid. Spans come from the grid dimensions.
- Beam schedule or beam elevations: size (width × depth), bottom bars, top bars at each support, stirrups and their spacing zones.
- Typical beam details: how far bottom bars extend into supports, how far support top bars extend into the span, hooks at exterior ends, lap locations.
- General notes: cover, lap schedule, hook rules.
If the bar arrangement itself is new to you, start with beam reinforcement explained. The short version: bottom bars carry tension near midspan, top bars carry tension over the supports of a continuous beam, and stirrups carry shear, which is why they are closer together near the supports. For more on the forces, see tension, compression, bending and shear.
The beam rebar calculation, group by group
| Group | Length comes from | Watch for |
|---|---|---|
| Bottom bars | Span + extension into each support | Hooks at exterior ends; bars per span vs continuous |
| Continuous top bars | Full beam length − end cover + hooks | Laps where the run is longer than stock |
| Extra top bars over supports | Length or extension each side shown on elevation | Measured from face or centreline |
| Stirrups | Perimeter + hook allowances | Spacing zones; closed vs open stirrups; double stirrups |
Hooks
Where a bar ends at an exterior column with a standard 90° hook, the typical ACI 318 value for the straight extension of the hook is 12 bar diameters: 9 in for a #6, 10.5 in for a #7. The project's details and the governing code decide; detailers use hook tables that also account for the bend. See rebar hooks and development length.
Stirrup count with zones
stirrups per span = (spaces in end zone 1) + (spaces in middle zone, rounded up) + (spaces in end zone 2) + 1
Measure the zones from the face of the support. The drawing normally shows where the first stirrup goes (often a couple of inches from the face); a takeoff that measures from the face is close enough and on the safe side.
Worked example: two-span beam B1
The drawings give:
- Beam B1, 12 in wide × 24 in deep, two spans of 24'-0" between column centrelines. Columns are 16 in square. The beam runs from the outer face of one end column to the outer face of the other: 48'-0" + 16 in = 49'-4" (49.333 ft).
- Top: 2 #6 continuous, 2 in end cover, 90° hook down at each end (9 in each, 12 × 0.75 in). Lap for #6 top bars from the lap schedule: 3'-0". Stock bars 40 ft.
- Extra top at each exterior support: 2 #6, 7'-0" straight plus a 9 in hook.
- Extra top over the interior column: 2 #7 × 16'-0".
- Bottom: 3 #7 per span, extending 6 in into each support.
- Stirrups: #3 closed, 1.5 in cover, @ 4 in for 4'-0" from each column face, @ 10 in in the middle. Hook allowance for this stirrup detail: 4 in per hook, two hooks (assumed from the detailing standard for this example).
Continuous top bars
Straight length = 49.333 − 2 × (2 ÷ 12) = 49.0 ft. With two hooks: 49.0 + 2 × 0.75 = 50.5 ft.
50.5 ft is longer than a 40 ft stock bar, so each line needs one lap: 50.5 + 3.0 = 53.5 ft per line.
Two lines = 107.0 ft of #6.
Extra top bars at exterior supports
7.0 + 0.75 = 7.75 ft each. 2 bars × 2 ends = 4 bars × 7.75 = 31.0 ft of #6.
Extra top bars over the interior support
2 × 16.0 = 32.0 ft of #7.
Bottom bars
Clear span = 24'-0" − 16 in = 22'-8" (22.667 ft). Length = 22.667 + 0.5 + 0.5 = 23.667 ft (23'-8").
3 bars × 2 spans = 6 bars × 23.667 = 142.0 ft of #7.
Stirrups
Stirrup size = (12 − 3) × (24 − 3) = 9 in × 21 in out to out.
Cut length = 2 × (9 + 21) + 2 × 4 = 68 in = 5.667 ft.
Per span, clear span 272 in:
- End zones: 48 in ÷ 4 in = 12 spaces each
- Middle zone: 272 − 96 = 176 in ÷ 10 in = 17.6 → 18 spaces
- Stirrups = 12 + 18 + 12 + 1 = 43
Two spans = 86 stirrups × 5.667 ft = 487.3 ft of #3.
Summary for one beam B1
| Size | Items | Total length | Weight |
|---|---|---|---|
| #3 | Stirrups | 487.3 ft | × 0.376 = 183.2 lb |
| #6 | Continuous top + exterior top | 107.0 + 31.0 = 138.0 ft | × 1.502 = 207.3 lb |
| #7 | Bottom + interior top | 142.0 + 32.0 = 174.0 ft | × 2.044 = 355.7 lb |
| Net total | 746.2 lb |
Check: 183.2 + 207.3 + 355.7 = 746.2 lb. Multiply by the number of B1 beams on the framing plan. Bar weights are in the rebar sizes table.
Look at where the steel went. The stirrups alone are about a quarter of the beam's weight, and the laps and hooks on the top bars added 4.5 ft to every continuous bar. Both are easy to underestimate when you only look at the main bars.
Things to watch on beams
- Extension reference. "8'-0" each side" may be measured from the centreline or from the face of the support. The difference is half the column width on each side, on every bar.
- Bottom bars continuous or per span. Some designs run bottom bars through supports with laps; others stop them in each span. The elevation shows which.
- Double stirrups and crossties. Wide beams or beams with many bars may use two stirrups per set. Count both pieces.
- Side bars (skin reinforcement). Deep beams may have bars along the side faces. They appear in the section, not always on the elevation.
- Beams cast with slabs. Slab top bars may run over the beam; do not count them again with the beam.
- Stirrup rules. For how stirrup spacing is set and shown, see stirrups and ties. The same zone method is used for column ties.
Frequently asked questions
How do you calculate the number of stirrups in a beam?
Measure the clear span between support faces, split it into the spacing zones shown on the drawing, divide each zone length by its spacing (rounding up), add the spaces together and add one. Do it per span and multiply by the number of spans and beams.
How do you calculate stirrup cut length?
Take the beam width and depth minus cover on each side to get the stirrup's outside dimensions, add up the perimeter, and add the hook allowances for the hook type and bar size from your detailing standard or the fabricator's table. Use the same convention throughout the takeoff.
Why are stirrups closer near the supports?
Shear force in a beam is usually highest near the supports, so the design often puts stirrups closer together there. For the takeoff, treat each spacing zone separately; using one average spacing for the whole beam gives the wrong count.
Do top bars in a beam need laps?
When a continuous top bar is longer than the stock bar, it has to be spliced, and every splice adds one lap length. Take the lap length from the project's lap schedule; top bars often have a longer lap than bottom bars under many codes, so check which row of the table applies.
This article explains general practice for learning purposes. On a real project, the drawings, the general notes and the governing code always win.