What Is CMU? Concrete Masonry Units on Structural Drawings

CMU stands for concrete masonry unit, the hollow concrete block used to build walls. The most common unit is called 8x8x16 (nominal), but its actual size is 7-5/8 x 7-5/8 x 15-5/8 in, because the nominal size includes a 3/8 in mortar joint.
Nominal and actual CMU sizes
Block sizes are named by their nominal dimensions, so that a block plus one mortar joint fits an 8 in module. The first number is the wall thickness.
| Called | Actual size (in) | Actual size (mm) |
|---|---|---|
| 6 in CMU (6x8x16) | 5-5/8 x 7-5/8 x 15-5/8 | 143 x 194 x 397 |
| 8 in CMU (8x8x16) | 7-5/8 x 7-5/8 x 15-5/8 | 194 x 194 x 397 |
| 10 in CMU (10x8x16) | 9-5/8 x 7-5/8 x 15-5/8 | 244 x 194 x 397 |
| 12 in CMU (12x8x16) | 11-5/8 x 7-5/8 x 15-5/8 | 295 x 194 x 397 |
Because of the 8 in module, a course of block is 8 in high, and wall heights and opening positions on a good CMU drawing land on multiples of 8 in.
Where you see CMU on a drawing
On the drawing you will see 8" CMU or CMU WALL on plans and wall sections, usually with a reinforcing callout such as:
#5 @ 48" O.C. VERT, GROUT CELLS W/ REINF.SOLID GROUTorGROUT ALL CELLS(every cell filled)BOND BEAM W/ (2) #5 @ 48" O.C. AND AT TOP OF WALLHORIZ. JOINT REINF. @ 16" O.C.(ladder or truss wire in the mortar beds)
A standard 16 in block has two hollow cells, so cell centers fall at 8 in. That is why vertical bar spacing in CMU is almost always a multiple of 8: 16, 24, 32, 48 in. A bar sits in a cell, and that cell is filled with grout so the bar works with the wall. Cells without bars are often left hollow in a partially grouted wall.
A bond beam is a course of U-shaped or knock-out units that holds horizontal bars and is filled with grout. Bond beams appear at the top of the wall, at floor lines and over openings. More detail in rebar in CMU walls.
Worked example: block and vertical bars for one wall
An 8 in CMU wall is 40 ft long and 8 ft high, with #5 @ 48" O.C. VERT.
- Courses: 96 in / 8 in = 12 courses
- Blocks per course: 480 in / 16 in = 30 blocks
- Blocks: 12 x 30 = 360 blocks (before corners, openings and waste)
- Vertical bars: 480 / 48 = 10 spaces, plus 1 = 11 bars
- Bar length: 8 ft wall height plus the lap to the footing dowels, as shown in the wall section
A useful check: one nominal block face is 8 x 16 = 128 sq in, so 100 sq ft of wall takes 14,400 / 128 = 112.5 blocks. The wall here is 320 sq ft, and 3.2 x 112.5 = 360. The two methods agree.
A common mistake
Reading 8" CMU as an 8 in actual thickness. The wall is 7-5/8 in thick, which matters when you check cover or fit two bars in one cell. The second mistake, for a rebar estimator, is forgetting the steel that is not drawn on the plan: footing dowels, bars at each side of openings, bond beam bars and lintel bars. See lintel reinforcement for the steel over doors and windows.
Frequently asked questions
Is CMU the same as cinder block?
People often use the two words for the same block. On structural drawings the term is CMU, and the units are specified by a standard and a strength in the project's specifications, so use those rather than the everyday name.
What does grouted cell mean?
It is a hollow cell of the block that is filled with grout, a fluid concrete mix. Cells with rebar are always grouted; a fully grouted wall has every cell filled.
Why is CMU rebar spacing 16, 24, 32 or 48 inches?
The cells in a standard block are 8 in apart, so a bar spacing has to be a multiple of 8 in for every bar to land in a cell. Other abbreviations around CMU walls are in structural drawing abbreviations.
This article explains general practice for learning purposes. On a real project, the drawings, the general notes and the governing code always win.