Lintel Reinforcement: Bars, Bearing and How Lintels Show in Schedules

6 min read · By a practising structural engineer · Updated November 2026

Installation and reinforcement of a new CMU block wall
Photo: MTA Capital Construction Mega Projects, CC BY 2.0, via Wikimedia Commons

Lintel reinforcement is the steel in the short beam that spans over a door or window opening. A lintel is a small simply supported beam: it sags under the wall above, so its main bars are at the bottom, with lighter top bars and stirrups holding the cage together and carrying shear near the ends. The lintel extends past each side of the opening onto the wall, and that bearing length is part of its length in the takeoff.

Lintels are small, but a building has dozens of them, and they are easy to miss because they often appear only in a schedule and on the elevations.

Why lintel reinforcement goes at the bottom

A lintel picks up the load of the wall (and sometimes a floor) above the opening and carries it to the wall on each side. It behaves like a simply supported beam: the bottom face is stretched at midspan, so the tension steel goes at the bottom. Near the ends, shear is highest, and that is where stirrups count most.

The top bars in a small lintel are mostly there to hold the stirrups in position. In a lintel that continues over several openings, or that is part of a continuous bond beam, there can be real negative moment over the piers between openings, and the top bars then do structural work. The drawing tells you which case you have. For the general picture of beam steel, see beam reinforcement explained.

. . .OPENINGBEARINGCLEAR SPAN
Lintel over an opening. The main bars (red, bottom) and stirrups run the full lintel length, which is the clear span plus the bearing at each end.

Bearing length

The lintel must sit on the wall beyond the opening on both sides. That extra length on each side is the bearing. It spreads the reaction into the wall and gives the bottom bars room to anchor.

The bearing is set by the engineer or the masonry standard the project follows. As a common reference point, US masonry practice calls for at least 4 in (102 mm) of bearing at each end, so the lintel is at least 8 in (203 mm) longer than the clear opening. Longer and more heavily loaded lintels often get more. Use the drawing value; if no bearing is given, raise a question rather than guessing.

Cast-in-place vs precast lintels

Type How it is built What the estimator takes off
Cast-in-place concrete Formed and poured over the opening, sometimes with the floor or a ring beam Rebar (bars + stirrups), concrete, formwork
Precast concrete Made in a plant, delivered and set on the wall Units by mark and length; the rebar is inside the product
Masonry (block) lintel U-shaped or bond beam blocks over the opening, bars placed, then grouted Rebar in the lintel course, grout, temporary support; see rebar in CMU walls
Steel angle or beam Steel section over the opening, common in brick veneer Not rebar: a miscellaneous steel item

The precast row is where estimators double count. If the schedule says PRECAST LINTEL 8" x 8" x 7'-4", the bars inside belong to the precaster. Do not add them to your rebar weight. You may still owe the anchorage or the bond beam the lintel sits under.

How lintels show on drawings

Lintels rarely get a full beam elevation. You find them in four places:

  1. A lintel schedule. A table with a mark (L1, L2), the maximum clear opening, size, bars and stirrups, and bearing. Openings are grouped by width, so one mark covers every opening up to that width.
  2. Plan tags. Each opening on the plan carries the lintel mark, or a note says "all openings up to 4'-0" use L1".
  3. Architectural elevations. These are the best place to count openings. Structural plans sometimes leave out small windows.
  4. A typical lintel detail. It shows bar positions, cover, hooks and bearing.

A typical schedule looks like this:

Mark Max clear opening Size (W x D) Bottom Top Stirrups Bearing
L1 4'-0" 8" x 8" 2-#4 none none 8"
L2 6'-0" 8" x 12" 2-#5 2-#4 #3 @ 6" 8"
L3 10'-0" 8" x 16" 3-#5 2-#4 #3 @ 6" 12"

(These values are an example layout, not design values.) If the table format is new to you, how to read a beam schedule covers the same kind of table.

Worked example: lintel reinforcement for ten L2 lintels

From the architectural elevations, 10 openings are 6'-0" clear and tagged L2. From the schedule:

  • L2: 8" x 12", bottom 2-#5, top 2-#4, stirrups #3 @ 6", bearing 8" each end.
  • Cover to bar ends: 1 1/2". First stirrup 2" from each end.
  • Bar list gives the #3 stirrup cut length as 3'-0".

Step 1: Lintel length. 72 in clear + 2 x 8 in bearing = 88 in (7'-4").

Step 2: Bar length. 88 - 2 x 1.5 = 85 in = 7.08 ft.

Step 3: Stirrup count. Zone between first and last stirrup: 85 - 2 x 2 = 81 in. 81 / 6 = 13.5, round up to 14 spaces, 15 stirrups.

Step 4: Weight per lintel. Bottom: 2 x 7.08 ft x 1.043 lb/ft = 14.78 lb. Top: 2 x 7.08 ft x 0.668 lb/ft = 9.46 lb. Stirrups: 15 x 3.0 ft x 0.376 lb/ft = 16.92 lb. Total: 41.16 lb per lintel.

Step 5: All ten. 10 x 41.16 = 411.6 lb (186.7 kg).

Step 6: Concrete. 8 in x 12 in x 88 in = 8,448 cu in = 4.89 cu ft per lintel, 48.9 cu ft (1.81 cu yd) for ten.

Notice the stirrups weigh more than the bottom bars here. That is common in short lintels, and it is why lintel stirrups are worth counting carefully instead of rounding them away.

Common mistakes

  • Counting from structural plans only. Check every opening on the architectural elevations.
  • Using the opening width as the lintel length. Add the bearing at both ends.
  • Adding rebar for precast lintels. The precaster supplies it.
  • Missing lintels that are part of a bond beam or ring beam. If the bond beam runs over the opening, the lintel bars may be extra bars added to the bond beam. Read the detail.
  • Ignoring the next size up. An opening of 6'-2" does not fit L2 (max 6'-0"). It goes to L3.

Frequently asked questions

Where should lintel reinforcement be placed?

The main bars go at the bottom, because a lintel sags between its bearings and the bottom face is in tension. Top bars and stirrups are added to hold the cage and carry shear, especially in deeper or longer lintels. The lintel schedule or detail gives the exact bars.

How much bearing does a lintel need?

The structural drawings set it. As a common reference point, US masonry practice calls for at least 4 in of bearing at each end (clear span plus 8 in overall). Longer or heavily loaded lintels often need more.

Do precast lintels need extra rebar on site?

Not inside the lintel itself, since the reinforcement is cast in at the plant. There may still be site bars where the lintel ties into a bond beam, a column or a ring beam. Check the detail where the lintel meets the wall.

How are lintels shown on structural drawings?

Usually with a mark at each opening and a lintel schedule that gives size, bars, stirrups and bearing for each mark. A typical detail shows bar positions and cover. Count the openings from the architectural elevations, then apply the schedule.

What is the difference between a lintel and a beam?

Structurally a lintel is a short beam over an opening in a wall. The word is used for small spans in wall construction, while "beam" is used for members in the main frame. The reinforcement logic is the same.

This article explains general practice for learning purposes. On a real project, the drawings, the general notes and the governing code always win.