Retaining Wall Rebar Takeoff: Stem, Base, Key and Dowels

8 min read · By a practising structural engineer · Updated November 2026

3D view of retaining wall rebar standing on its concrete footing
3D illustration: The Bending Moment

A retaining wall rebar takeoff splits the wall into its parts and takes each one off like its own element: the stem (vertical bars on each face plus horizontal bars), the base (transverse bars top and bottom across the heel and toe, plus longitudinal bars), the shear key if there is one, and the dowels that tie the footing to the stem. Bar lengths come from the typical section, counts come from the wall length divided by the spacing, and laps are added wherever a run is longer than stock.

The trick with retaining walls is that almost everything is in one typical section, repeated along the wall. Read that section carefully once and the rest is multiplication.

How a cantilever retaining wall is reinforced

A cantilever retaining wall is an upside-down T (or L). Soil pushes on the back of the stem, the stem bends like a cantilever fixed at the footing, and the footing resists overturning and sliding. If you want the structural picture first, see how a retaining wall works.

That behaviour decides where the heavy bars go:

  • Stem, back face (soil side): the main vertical bars. Soil pressure puts this face in tension.
  • Stem, front face: lighter vertical bars, mainly for shrinkage and temperature.
  • Stem horizontals: on both faces, for shrinkage, temperature and distribution.
  • Heel (under the retained soil): the soil weight presses the heel down, so the main heel bars are on top.
  • Toe (in front of the stem): the ground pushes the toe up, so the main toe bars are at the bottom.
  • Key: a downstand under the footing to help against sliding, with its own bars tied into the footing.
  • Dowels: bars cast in the footing that stick up and lap with the stem verticals, because the footing is poured first.
8'-0"front #4 @ 18"back face #5 @ 12"dowels, lap 2'-6"heel top #5 @ 12"toe bot #5 @ 12"key
Typical section of the example wall. Heavy bars on the soil face of the stem, on top of the heel and at the bottom of the toe; dowels from the footing lap with the stem verticals.

Reading the typical section

On the drawing you will usually find a wall elevation (showing length, steps in height and joints) and one or more typical sections. Tall walls often have several sections for different height ranges, each with different bars. Take each height range as its own run.

From each section write down:

  • Stem thickness and height above the footing.
  • Footing width, depth, toe and heel widths.
  • Key size and position.
  • Every bar callout, and which face it is on.
  • Dowel shape: the foot length on the bottom mat and the projection above the footing.
  • Cover for the footing and the stem. Typical ACI 318 practice for concrete cast against earth is 3 in, but the project's general notes and governing code win. See concrete cover.
  • Lap lengths from the general notes or lap table. See lap splice length.

From the elevation write down the length of each run, and any expansion or construction joints where bars stop.

Retaining wall rebar takeoff: worked example

One straight cantilever wall. Values are this example's; a real project's notes and code govern.

  • Wall length: 64'-0" (768 in). Stem 10 in thick, 8'-0" high above the footing.
  • Footing: 6'-6" wide (toe 1'-6" + stem 10" + heel 4'-2" = 78 in) × 1'-4" deep. Key 12 in × 12 in under the stem.
  • Cover: 3 in in the footing, 2 in in the stem and at the wall ends.
  • Stem: back face #5 @ 12" vertical, front face #4 @ 18" vertical, #4 @ 12" horizontal each face.
  • Footing: #5 @ 12" transverse top and bottom, #4 @ 12" longitudinal top and bottom.
  • Key: #5 @ 12" straight bars 2'-0" long, plus 2 #4 continuous.
  • Dowels: back face #5 @ 12" (12 in foot + 12 in in footing + 2'-6" lap above = 4'-6"); front face #4 @ 18" (12 in foot + 12 in + 2'-0" lap = 4'-0").
  • Laps for horizontal and longitudinal #4: 2'-0". Stock length 40 ft.
  • Weights: #5 = 1.043 lb/ft, #4 = 0.668 lb/ft.

Step 1: stem verticals

Length: they start at the top of the footing and stop 2 in below the top: 96 − 2 = 94 in = 7.833 ft.

Usable length for counting: 768 − 2 × 2 = 764 in.

  • Back face #5 @ 12": 764 ÷ 12 = 63.7, round up to 64 spaces, + 1 = 65 bars. 65 × 7.833 = 509.2 ft.
  • Front face #4 @ 18": 764 ÷ 18 = 42.4, round up to 43 spaces, + 1 = 44 bars. 44 × 7.833 = 344.7 ft.

Step 2: dowels

One dowel per stem vertical, at the same spacing.

  • Back face #5: 65 × 4.5 ft = 292.5 ft.
  • Front face #4: 44 × 4.0 ft = 176.0 ft.

Step 3: stem horizontals

Bar length per line: 768 − 4 = 764 in = 63.67 ft. That is longer than a 40 ft stock bar, so each line needs one lap: 63.67 + 2.0 = 65.67 ft.

Lines per face: (96 − 2 − 2) ÷ 12 = 7.7, round up to 8 spaces, + 1 = 9. Two faces = 18 lines.

Total: 18 × 65.67 = 1,182.0 ft of #4.

Step 4: footing transverse bars (heel and toe)

Here the main heel bars (top) and main toe bars (bottom) run the full footing width, which is common in simple walls. Length: 78 − 2 × 3 = 72 in = 6.0 ft.

Count along the wall: (768 − 6) ÷ 12 = 63.5, round up to 64 spaces, + 1 = 65 per layer. Two layers = 130 bars.

Total: 130 × 6.0 = 780.0 ft of #5.

On heavier walls the top heel bars and bottom toe bars are often different sizes, or stop short, so read the section rather than assuming both layers match.

Step 5: footing longitudinal bars

Lines per layer: 72 ÷ 12 = 6 spaces, + 1 = 7. Top and bottom = 14 lines.

Length per line: 768 − 6 = 762 in = 63.5 ft, + one 2'-0" lap = 65.5 ft.

Total: 14 × 65.5 = 917.0 ft of #4.

Step 6: key

  • Key bars #5 @ 12": 65 × 2.0 ft = 130.0 ft.
  • Key longitudinal 2 #4: 2 × 65.5 = 131.0 ft.

Step 7: weight

Item Size Total length (ft) lb/ft Weight (lb)
Stem verticals, back face #5 509.2 1.043 531.1
Stem verticals, front face #4 344.7 0.668 230.3
Dowels, back face #5 292.5 1.043 305.1
Dowels, front face #4 176.0 0.668 117.6
Stem horizontals, both faces #4 1,182.0 0.668 789.6
Footing transverse, top and bottom #5 780.0 1.043 813.5
Footing longitudinal, top and bottom #4 917.0 0.668 612.6
Key bars #5 130.0 1.043 135.6
Key longitudinal #4 131.0 0.668 87.5
Total 3,622.8

Check by size: #5 = 509.2 + 292.5 + 780.0 + 130.0 = 1,711.7 ft × 1.043 = 1,785.3 lb. #4 = 344.7 + 176.0 + 1,182.0 + 917.0 + 131.0 = 2,750.7 ft × 0.668 = 1,837.5 lb. Sum = 3,622.8 lb. The two routes agree within rounding of the individual lines.

That is the net weight. A waste allowance goes on top as a separate line; see rebar waste factor. The rebar weight calculator is handy for checking weight per foot.

Where retaining wall takeoffs go wrong

  • Missing the dowels. The dowels are often shown only in the section, not in any callout list. On this wall they are about 12% of the total weight.
  • One section for the whole wall. Walls that step down in height usually change bars with height. Split the elevation into runs and use the right section for each.
  • Ignoring laps on long runs. Every continuous bar longer than stock needs laps. On long walls with horizontals on both faces, laps add up quickly.
  • Corners and returns. Where a wall turns a corner, the detail often shows corner bars (L-bars) at each horizontal line. Count them as their own item.
  • Joints. If the elevation shows construction or expansion joints, bars may stop and restart there. A bar run that stops at a joint has no lap across it but may have dowels or none at all, depending on the joint detail.
  • Counterforts and buttresses. Some tall walls have counterforts behind the stem. Those are separate elements with their own bars.

The stem is a wall like any other once you have its bars, so the method in rebar estimate for walls applies. The base follows the strip-footing method in rebar estimate for footings.

Frequently asked questions

Which face of a retaining wall gets the main reinforcement?

In a cantilever retaining wall the main vertical bars go on the soil side (back face) of the stem, because the soil pressure puts that face in tension. In the base, the heel's main bars are on top and the toe's main bars are at the bottom. Always confirm on the section, since some walls are designed differently.

Why does a retaining wall need dowels?

The footing is poured first and the stem later. Dowels are bars cast into the footing that stick up and lap with the stem bars, so the stem is tied to the footing across the construction joint. They are a separate bar mark and must be counted separately.

How do you count rebar along a retaining wall?

Take the wall length minus the end cover, divide by the bar spacing, round up, and add one. Do this for each face and each bar spacing separately. For horizontal bars, count the lines up the stem height the same way, then multiply by the length of each line including laps.

How much rebar is in a retaining wall per foot?

It depends entirely on wall height, soil and design, so there is no single number. In the example here, a 64 ft wall with an 8 ft stem came to about 3,623 lb, roughly 57 lb per foot of wall. Use a figure like that only to check your own takeoff, never instead of one.

This article explains general practice for learning purposes. On a real project, the drawings, the general notes and the governing code always win.

Keep reading

The whole library

Free download

The Rebar Callout Cheat Sheet

One printable page: the five questions every callout answers, four labels decoded, and the same bar in six notations. Keep it next to the set of plans.

Plus a few short emails on reading structural drawings. Unsubscribe any time. Privacy.