Footing Rebar Calculation: Spread Footings, Strip Footings and Dowels

A footing rebar calculation has three parts: the bottom mat (bars each way in a spread footing, or longitudinal and transverse bars in a strip footing), any top bars, and the dowels that connect the footing to the column or wall above. For each part you count the bars, take the footing dimension minus cover for the length, add laps and hooks from the details, then convert length to weight by bar size.
Footings are usually the first thing an estimator takes off, and they are a good place to build the habit of reading the schedule, the section and the typical details together.
Where footing rebar is shown on the drawings
Foundation information is spread over several places:
- Foundation plan: footing marks (F1, F2, SF1) and their locations, so you can count them. If the foundation system itself is unfamiliar, see foundation types on drawings.
- Footing schedule: size, depth and bars for each mark, e.g.
F2 8'-0" × 8'-0" × 2'-0" 9 #6 EW BOT. - Footing sections: bar positions, top bars if any, hooks, step details.
- Typical details: column dowels, wall dowels, corner bars in strip footings, steps in footing levels.
- General notes: cover (for concrete cast against earth, typical ACI 318 practice is 3 in), lap splice table, concrete strength. The project's own notes and governing code always win; see concrete cover.
| Footing part | Usually found in | Typical callout |
|---|---|---|
| Bottom mat, spread footing | Footing schedule | 9 #6 EW BOT |
| Top mat (large or uplift footings) | Schedule or section | #5 @ 12" EW TOP |
| Longitudinal bars, strip footing | Section | 3 #5 CONT |
| Transverse bars, strip footing | Section | #4 @ 12" |
| Column dowels | Column schedule or typical detail | 4 #7 DOWELS |
| Wall dowels | Wall section | #4 @ 16" |
| Corner bars, strip footing | Typical detail | match longitudinal bars |
Footing rebar calculation for a spread footing
A spread (isolated) footing is a square or rectangular pad under one column. The bars run both ways in the bottom of the footing.
Bar length = footing dimension − cover at both ends (+ hooks, if the detail shows them).
If the schedule gives a count ("9 #6 EW"), use it directly. If it gives a spacing, count bars as (footing width − 2 × cover) ÷ spacing, rounded up, + 1.
"EW" means each way, so 9 #6 EW is 18 bars per footing. A common mistake is to take only 9.
Worked example 1: six spread footings with column dowels
The drawings give:
- Footing schedule: F2, 8'-0" × 8'-0" × 2'-0", 9 #6 EW bottom, straight bars. Quantity on the foundation plan: 6.
- Cover: 3 in (general notes).
- Column dowel detail: 4 #7 dowels per column, L-shaped, foot of 1'-0" resting on the bottom mat, projecting 2'-6" above the top of footing for the lap with the column bars.
Bottom mat
Length = 96 in − 3 in − 3 in = 90 in = 7.50 ft.
Bars per footing = 9 × 2 = 18. Total = 6 × 18 = 108 bars.
Total length = 108 × 7.50 = 810.0 ft.
Weight = 810.0 × 1.502 lb/ft = 1,216.6 lb of #6.
Column dowels
The dowel foot sits on top of the two layers of #6 bars. Bottom of the vertical leg above the footing base = 3 in cover + 0.75 in + 0.75 in = 4.5 in.
Vertical leg inside the footing = 24 in − 4.5 in = 19.5 in.
Vertical leg total = 19.5 in + 30 in projection = 49.5 in.
Cut length = 49.5 in + 12 in foot = 61.5 in = 5.125 ft (5'-1½").
Total = 6 footings × 4 = 24 dowels × 5.125 ft = 123.0 ft.
Weight = 123.0 × 2.044 lb/ft = 251.4 lb of #7.
On real drawings the dowel detail may give the leg lengths directly. When it gives a rule instead ("extend to bottom mat, project lap length"), you work it out as above.
Footing rebar calculation for a strip footing
A strip (continuous) footing runs under a wall. On a house it often follows the whole perimeter. Its bars are:
- Longitudinal bars running the length of the footing, lapped where they exceed stock length.
- Transverse bars across the width, at a spacing.
- Corner bars at corners and intersections, from a typical detail.
- Wall dowels at a spacing, to tie in the wall.
For a closed loop (a footing that goes all the way round), the number of transverse bars or dowels is simply length ÷ spacing. There is no "+1" because the first and last bar are the same position.
Measure the run along the centreline of the footing. Measuring the outside perimeter overstates the length; measuring the inside understates it.
Worked example 2: a perimeter strip footing
The drawings give:
- Strip footing SF1, 2'-0" wide × 1'-0" deep, around a 40'-0" × 20'-0" rectangle measured on the footing centreline. Run = 2 × (40 + 20) = 120 ft.
- Section: 3 #5 continuous longitudinal, #4 @ 12" transverse, 3 in cover.
- Lap schedule: 2'-6" for #5 (from this project's general notes). Stock bars: 40 ft.
- Typical detail: corner bars matching the longitudinal bars, 2'-6" each leg, at every corner.
- Wall section: #4 dowels @ 16", each 3'-0" total cut length as detailed.
Longitudinal bars
Each 40 ft bar adds 40 − 2.5 = 37.5 ft of new run after its lap.
Bars per line = 120 ÷ 37.5 = 3.2 → 4 bars, so 4 laps in the closed loop.
Length per line = 120 + 4 × 2.5 = 130.0 ft. Three lines = 390.0 ft.
Corner bars
4 corners × 3 bars × (2.5 + 2.5 ft) = 60.0 ft.
Total #5 = 390.0 + 60.0 = 450.0 ft × 1.043 = 469.4 lb.
Transverse bars
Length = 24 in − 3 in − 3 in = 18 in = 1.50 ft.
Number = 120 ft ÷ 1 ft = 120 bars (closed loop).
Total = 120 × 1.50 = 180.0 ft of #4.
Wall dowels
Number = 120 ft × 12 ÷ 16 in = 90 dowels.
Total = 90 × 3.00 = 270.0 ft of #4.
Total #4 = 180.0 + 270.0 = 450.0 ft × 0.668 = 300.6 lb.
Summary of both examples
| Size | Item | Total length | Weight |
|---|---|---|---|
| #4 | SF1 transverse + wall dowels | 450.0 ft | 300.6 lb |
| #5 | SF1 longitudinal + corner bars | 450.0 ft | 469.4 lb |
| #6 | F2 bottom mat | 810.0 ft | 1,216.6 lb |
| #7 | F2 column dowels | 123.0 ft | 251.4 lb |
| Net total | 2,238.0 lb |
Check: 300.6 + 469.4 + 1,216.6 + 251.4 = 2,238.0 lb. This is a net figure. Any waste allowance goes on top as a stated percentage; see rebar waste factor. Bar weights can be checked with the rebar weight calculator.
Things to watch on footings
- Top bars. Thick footings, combined footings and footings resisting uplift may have a top mat. It is in the section, not always in the schedule.
- Hooks at bar ends. Some details hook the bottom bars up at the ends. Each hook adds length; take its size from the detail or hook table.
- Footing steps. Where a strip footing steps down a slope, the step detail adds vertical and extra horizontal bars.
- Intersections. A T-junction of strip footings has its own corner or junction bars in the typical detail.
- Dowels in two places. Column dowels can appear in both the footing schedule and the column schedule. Count them once.
- Concrete quantities. If you are also pricing concrete, the same footing dimensions feed the concrete volume estimate.
Frequently asked questions
How do you calculate rebar for a footing?
Count the bars from the schedule (or from the spacing), take the footing dimension minus cover at both ends as the bar length, add hooks and laps from the details, and multiply the total length by the bar weight per foot. Do the bottom mat, top mat and dowels as separate lines.
What does "EW" mean in a footing schedule?
EW means each way. "9 #6 EW" means 9 bars in one direction and 9 bars in the other, 18 bars in total per footing. Taking only 9 is one of the most common footing takeoff errors.
Are column dowels part of the footing or the column takeoff?
Either works, as long as they are counted once. Many estimators include them with the footing because they are placed before the footing pour, but check where they appear on the drawings and note your choice in the takeoff.
How much cover is used for footing rebar?
Typical ACI 318 practice for concrete cast against and permanently exposed to earth is 3 in. The project's general notes give the value to use, and other codes and project specifications may differ.
This article explains general practice for learning purposes. On a real project, the drawings, the general notes and the governing code always win.