Post Tensioned Slab Drawings: Tendons, Anchors, Profiles and the Rebar That Is Still There

8 min read · By a practising structural engineer · Updated November 2026

3D view of a beam cage with draped post-tensioning ducts on formwork
3D illustration: The Bending Moment

Post tensioned slab drawings show high-strength steel tendons that are stretched after the concrete hardens, laid out in plan (usually banded along column lines one way and distributed the other way), with anchors at the slab edges and a profile that tells the installer how high each tendon sits. Ordinary reinforcing bars, called mild steel, are still present at columns, at anchors and in the bottom of the slab. The rebar estimator counts that mild steel; the tendons belong to the post-tensioning supplier.

What post-tensioning does in a slab

A post tensioned (PT) slab uses tendons, most often 0.5 in (12.7 mm) seven-wire strand to ASTM A416, which are pulled with a hydraulic jack once the concrete has reached the strength the drawings call for. The jack stretches the strand, it is locked off at the anchor, and the slab is squeezed into compression.

The tendon is not straight. It is draped: high over the supports, low at mid-span. When a curved tendon is pulled tight, it pushes upward on the concrete along the span, balancing part of the slab's own weight. This is why PT slabs can be thinner than conventionally reinforced slabs for the same span, and why they are common in parking structures, apartment towers and offices.

Two systems exist:

  • Unbonded: each strand is greased and sheathed in plastic, so it can slide inside the concrete. This is the common system in US building slabs.
  • Bonded: several strands sit inside a metal or plastic duct that is grouted after stressing. Common in bridges, transfer beams and in many slabs outside the US.

What you will find on a set of post tensioned slab drawings

PT slabs usually come with two sets of documents: the structural engineer's drawings and the PT supplier's shop drawings (installation drawings). The structural set shows the design intent: number of tendons, the force they must deliver, high and low points, and the mild steel. The shop drawings show every tendon with its exact length, anchor locations and the profile heights the crew will set.

Tendon layout in plan

The most common layout for a two-way flat plate in the US is banded in one direction, distributed in the other:

  • Banded tendons are grouped tightly in a narrow strip running over the columns along one grid direction. On the plan you will see a thick band along the column line with a tag such as (12) TENDONS or a force in kips.
  • Distributed tendons run perpendicular to the bands, spread more or less evenly across the slab at a set spacing, for example TENDONS @ 48" O.C.

Beams and one-way slabs have their own patterns, but the reading logic is the same: count, direction, spacing, and where each tendon starts and ends. For the structural difference between slab systems, see one-way vs two-way slabs.

Anchors

Every tendon has a stressing end, where the jack is applied, and a dead end (fixed end), which is cast in. Long tendons may be stressed from both ends. On the plan, anchors are drawn as small symbols at the slab edge, often with a filled triangle or a letter key. Intermediate stressing points inside a long pour appear at construction joints or pour strips.

The anchor zone carries a large concentrated force, so the typical details show bursting and back-up reinforcement behind the anchors: hairpins, short bars or continuous bars along the slab edge. These are mild steel and belong in the rebar takeoff.

Tendon profile

The profile tells the crew how high each tendon sits above the soffit at each control point. You will see it in two ways:

  1. A profile elevation along the tendon: a curve with heights written at the high points over supports and at the low point in the span, measured to the center of gravity of the strand (CGS).
  2. Numbers on the plan written along each tendon, for example 1 3/4 near mid-span and 6 1/4 over a column, giving the height in inches from the bottom of the slab.

The installer sets support chairs to those heights. Profile errors are expensive because they change the uplift the tendon gives, which is why inspectors check them before the pour.

high pointlow pointmild steel top barsdead endstressing endtendon drawn in red
A draped tendon over two spans: high over the supports, low near mid-span. The dashed bars over the interior support are mild steel.

The mild steel is still there

A frequent beginner's assumption is that a PT slab has no rebar. It usually has a fair amount, just less than a conventionally reinforced slab. Expect to find:

Mild steel item Where it appears on drawings Counted by rebar estimator?
Top bars over columns Plan callout at each column, e.g. T 6-#5 x 10'-0" E.W. Yes
Bottom bars in spans Plan or typical note, sometimes only at certain bays Yes
Back-up and bursting bars at anchors Typical anchor detail Yes
Bars around openings Typical opening detail Yes
Edge and corner bars Typical slab edge detail Yes
Support bars for tendon chairs PT shop drawings or spec Check scope: often the PT installer's
Tendons, anchors, sheathing, grease, wedges PT plans and shop drawings No, PT supplier
Tendon support chairs PT shop drawings Usually no, PT supplier

Scope splits vary by contract, so read the specification sections for post-tensioning and for concrete reinforcing before you exclude anything. The line between "rebar" and "PT accessories" is a classic place for gaps between two bids.

Worked example: what the rebar estimator counts in a PT floor

Take a flat plate 90 ft x 60 ft (27.4 m x 18.3 m) with columns on a 30 ft grid: 4 column lines one way, 3 the other, so 12 columns. The drawings show (example values):

  • Banded tendons: 10 tendons in each of the 3 bands running the 90 ft direction
  • Distributed tendons running the 60 ft direction at 48 in on center
  • At every column: T 6-#5 x 10'-0" E.W. (6 top bars each way)
  • Slab edge detail: 2-#4 CONT. along all four edges behind the anchors
  • Lap for #4 in the general notes: 24 in. Stock length 20 ft.

Step 1: tendons (count, but do not price as rebar). Banded: 3 x 10 = 30 tendons. Distributed: 90 ft x 12 / 48 = 22.5 spaces, so 23 spaces and 24 tendons. That is 54 tendons and 108 anchors. These numbers are useful for checking the anchor zone bars, but the tendons themselves go to the PT supplier.

Step 2: top bars at columns. Per column: 6 bars each way = 12 bars x 10 ft = 120 ft. For 12 columns: 1,440 ft of #5 at 1.043 lb/ft = 1,502 lb.

Step 3: edge bars. Perimeter = 2 x (90 + 60) = 300 ft. A closed loop with 20 ft bars and 2 ft laps: 300 / 18 = 16.7, so 17 bars and 17 laps. Length per line = 300 + 17 x 2 = 334 ft. Two lines = 668 ft of #4 at 0.668 lb/ft = 446 lb.

Step 4: what is still open. Bottom bars, if the plan shows any, bars around openings, anchor hairpins from the typical detail (counted per anchor, which is why step 1 matters), and waste. Mild steel for this floor so far: about 1,950 lb.

Notice how small that number is compared with a conventionally reinforced slab of the same area. Missing a typical anchor detail or the opening detail can be a large share of a PT job's mild steel.

Reading tips and common mistakes

  • Find the PT general notes. They give concrete strength at stressing, the strand type, the effective force per tendon, and the sequence. They also give the minimum cover to tendons.
  • Compare the structural drawings with the shop drawings. The rebar quantities come from the structural set; the shop drawings help you locate bars that interfere with anchors.
  • Do not take off tendons as rebar. Tendons drawn in plan look like long bars to a beginner.
  • Mark "no core, no drill" zones. Drilling into a stressed tendon is dangerous and costly. Drawings and slab markings usually warn about it, and you should know they exist even as an estimator.
  • Check the typical details sheet first. In PT slabs, a large share of the mild steel lives in typical details rather than on the plan. See typical details and hidden rebar.

If you are new to reading full sets, start with how to read structural drawings, then come back to the PT sheets. Shear around columns is a design concern in flat plates of every kind; the punching shear video shows what happens at a column. For bar weights, use the rebar sizes reference.

Frequently asked questions

Do post tensioned slabs have rebar?

Yes. Almost all PT slabs contain mild steel: top bars over columns, bars at anchors, around openings and at edges, and often some bottom bars. The amount is smaller than in a conventionally reinforced slab, but it has to be counted.

What is the difference between banded and distributed tendons?

Banded tendons are bundled in a narrow strip over the column line in one direction. Distributed tendons are spread across the slab at a regular spacing in the other direction. Together they give a two-way PT flat plate its strength.

What does the tendon profile on a PT drawing show?

It shows the height of the tendon above the bottom of the slab at control points, typically the high points over supports and the low point in each span. Installers set tendon chairs to those heights before the pour.

Who installs the rebar in a post tensioned slab?

It depends on the contract. The tendons and anchors are typically supplied and installed under the post-tensioning scope, while the mild steel is usually in the reinforcing steel scope. The specifications state the split, so read both sections.

Can you drill into a post tensioned slab?

Only after the tendons are located, usually by scanning, and with the engineer's approval. Cutting a stressed tendon can release a large force and damages the slab's capacity.

This article explains general practice for learning purposes. On a real project, the drawings, the general notes and the governing code always win.

Keep reading

The whole library

Free download

The Rebar Callout Cheat Sheet

One printable page: the five questions every callout answers, four labels decoded, and the same bar in six notations. Keep it next to the set of plans.

Plus a few short emails on reading structural drawings. Unsubscribe any time. Privacy.